 PSC Series Data Sheet 6 to 12 A Switching Regulators
Input voltage up to 144 VDC Single output of 3.3 to 36 VDC No input-to-output isolation
Features
* * * * RoHS lead solder exemption compliant Efficiency up to 97% Low input-output differential voltage No derating over temperature
Model Selection
Output Vo nom Io nom [VDC] [A] 3.3 12 5.1 10 5.1 11 5.1 12 12 6 12 8 12 9 15 6 15 8 15 9 24 6 24 8 24 9 36 6 36 8 48 6 Input voltage Vi [VDC] 8 - 40 8 - 80 8 - 40 7 - 40 18 - 144 15 - 80 15 - 40 22 - 144 19 - 80 19 - 40 31 - 144 29 - 80 29 - 60 44 - 144 42 - 80 58-144 Rated power Po tot [W] 39.6 51 56.1 61.2 72 96 108 90 120 135 144 192 216 216 288 288 Efficiency h typ [%] 77 79 79 83 89 90 90 90 91 91 94 94 94 95 96 97 Type Options
PSC 3E12-2 PSC 5A10-7iR PSC 5A11-2 PSC 5A12-7iR PSC 126-7iR PSC 128-7iR PSC 129-2 PSC 156-7iR PSC 158-7iR PSC 159-2 PSC 246-7iR PSC 248-7iR PSC 249-2 PSC 366-7iR PSC 368-7iR PSC 486-7iR
iR-Package -9, L, P, C, D iR-Package -9, L, P, C, D -9, L, P, C, D -9, L, P, C, D iR-Package -9, L, P, C, D -9, L, P, C, D iR-Package -9, L, P, C, D -9, L, P, C, D iR-Package -9, L, P, C, D -9, L, P, C, D -9, L, P, C, D
APR 05, 2004 revised to JUN 06, 2006
Page 1 of 3
www.power-one.com
PSC Series Data Sheet 6 to 12 A Switching Regulators
Input
Input voltage No load input current refer to selection chart -50 mA
Output
Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel
Vi nom, Io nom Vi nom, Io nom IEC/EN 61204, total Vi min - Vi max, Io nom Vi nom, 0 - Io nom not required rectangular U/I characteristic by current limitation
up to 96% 0.6% Vo nom typ. 0.4% typ. 0.3% typ. 0.3% 0A typ. 110% Io nom
Protection
Input reverse polarity Input undervoltage lockout Input transient protection Output Output overvoltage with external fuse (built-in fuse with option C installed) typ. 80% Vi min suppressor diode no-load, overload and short circuit proof suppressor diode typ. 150% Vo nom
Safety
Approvals Protection degree Electric strength test voltage EN 60950, UL 1950, CSA C22.2 No. 950 I/case and O/case IP 20 500/750/1500 V DC
EMC
Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 CISPR 22/EN 55022
Environmental
Operating ambient temperature Operating case temperature TC Storage temperature Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF -2, Vi nom, Io nom, convection cooled -2, Vi nom, Io nom -2, non operational -7, Vi nom, Io nom, convection cooled -7, Vi nom, Io nom -7, non operational IEC/EN 60068-2-3 IEC/EN 60068-2-6 IEC/EN 60068-2-27 IEC/EN 60068-2-29 IEC/EN 60068-2-64 MIL-HDBK-217 -10 to 50C -10 to 80C -25 to 100C -25 to 71C -25 to 95C -40 to 100C
Options
Extended temperature range -40 to 71C, (ambient) Inhibit, TTL input, output(s) enabled if left open Output voltage adjust 0 - 108% Vo nom Output voltage adjust potentiometer 8% Vo nom Additional internal input filter Thyristor crowbar on output Input/output undervoltage monitor
APR 05, 2004 revised to JUN 06, 2006 Page 2 of 3
-9 i R P L C D/D1
www.power-one.com
PSC Series Data Sheet 6 to 12 A Switching Regulators
Mechanical data
Tolerances 0.3 mm (0.012") unless otherwise indicated.
Yellow LED output voltage indicator
6.3 x 0.8
European Projection
09023
Potentiometer (option D) Ut
Potentiometer (option P)
2.8 x 0.8
Uo D Go- R Vo+ i
Vi+
Gi-
Uo G
6.35 1
151 1 Distance between M4 mounting screws 144
8.1 1
32.2 0.5
88 1
(45)
Measuring point of case temperature TC
5 0.5
4.3
43 1
12.5 1
7.5
27.5
7.5
18.5 11.3 40
7.5 10 7.5 10 (14)
Accessories
Isolation pads for easy and safe PCB mounting Ring core chokes for ripple and interference reduction
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
10 2
7 2
APR 05, 2004 revised to JUN 06, 2006
Page 3 of 3
www.power-one.com
min. 8